The OW9800 Series includes the OW9820 and OW9825 high-voltage digital multimeters. OW9820 supports voltage measurement up to 2000V, while OW9825 supports measurement up to 2500V. Both models feature a 3 5/6-digit True RMS display and support AC/DC voltage, AC/DC current, resistance, capacitance, frequency, diode, continuity, and temperature measurements. The multimeter provides full-range anti-burn and overload protection for enhanced safety during electrical testing. Additional functions include non-contact voltage detection, relative measurement, data hold, overload indication, low-battery alert, and customizable auto power-off. Its double-injection molded housing combines a hard plastic structure, PC inner frame, and soft TPU outer layer to provide improved durability and grip. The OW9800 Series is suitable for high-voltage electrical testing, industrial maintenance, power-system troubleshooting, and field-service applications.
| Models | Available Models | OW9820, OW9825 |
| DC Voltage | Measurement Range | 600 mV to 1000 V; up to 2000 V (OW9820) / 2500 V (OW9825) |
| Accuracy | ±(0.5% + 5) to ±(1.0% + 6), depending on range | |
| AC Voltage | Measurement Range | 6 V to 750 V; up to 2000 V |
| Accuracy | ±(0.8% + 10) to ±(1.2% + 10), depending on range | |
| DC Current | Measurement Range | 600 μA to 600 mA |
| Accuracy | ±(1.0% + 10) to ±(1.2% + 10) | |
| AC Current | Measurement Range | 600 μA to 600 mA |
| Accuracy | ±(1.5% + 10) | |
| Resistance | Measurement Range | 600 Ω to 60 MΩ |
| Accuracy | ±(0.8% + 4) to ±(1.2% + 10) | |
| Capacitance | Measurement Range | 10 nF to 20 mF |
| Accuracy | ±(3.5% + 20) to ±(10% + 0D), depending on range | |
| Frequency | Measurement Range | 10 Hz to 10 MHz |
| Accuracy | ±(0.5% + 10) | |
| Diode | Diode Test | Forward voltage drop; test current approximately 0.4 mA; open-circuit voltage approximately 3.0 V |
| Continuity | Continuity Test | Buzzer sounds below approximately 50 Ω ± 20 Ω |
| Temperature | Measurement Range | -20°C to 1000°C |
| Resolution | 1°C | |
| Accuracy | <400°C: ±(1.0% + 5); ≥400°C: ±(1.5% + 15) | |
| Display | Resolution | 3 5/6 digits |
| Input | Input Impedance | Approximately 10 MΩ |
| Safety | High-Voltage Measurement | Up to 2000 V (OW9820) / 2500 V (OW9825) |
| Overload Protection | Full-range anti-burn and overload protection | |
| NCV | Non-contact voltage detection supported | |
| Functions | Additional Functions | Relative Measurement, Data Hold, Overload Indication, Low Battery Alert, Auto Power-Off |